619 research outputs found
The IRAS Minor Planet Survey
This report documents the program and data used to identify known asteroids observed by the Infrared Astronomical Satellite (IRAS) and to compute albedos and diameters from their IRAS fluxes. It also presents listings of the results obtained. These results supplant those in the IRAS Asteroid and Comet Survey, 1986. The present version used new and improved asteroid orbital elements for 4679 numbered asteroids and 2632 additional asteroids for which at least two-opposition elements were available as of mid-1991. It employed asteroid absolute magnitudes on the International Astronomical Union system adopted in 1991. In addition, the code was modified to increase the reliability of associating asteroids with IRAS sources and rectify several shortcomings in the final data products released in 1986. Association reliability was improved by decreasing the position difference between an IRAS source and a predicted asteroid position required for an association. The shortcomings addressed included the problem of flux overestimation for low SNR sources and the systematic difference in albedos and diameters among the three wavelength bands (12, 25, and 60 micrometers). Several minor bugs in the original code were also corrected
Invariants of the Haldane-Shastry Chain
Using a formalism developed by Polychronakos, we explicitly construct a set
of invariants of the motion for the Haldane-Shastry chain.Comment: 11 pages, UVA-92-0
A comparison of two fat suppressed magnetic resonance imaging pulse sequences to standard T2-weighted images for brain parenchymal contrast and the identification of lesions in dogs with inflammatory intracranial disease
T2-weighted sequences are commonly relied upon in magnetic resonance (MR) imaging
protocols for the detection of brain lesions in dogs. Previously the effect of fluid suppression via
fluid attenuated inversion recovery (FLAIR) has been compared to T2-weighting with mixed
results. Short tau inversion recovery (STIR) has been reported to increase the detection of some
CNS lesion in people. The purpose of the current study was to evaluate the effect of fat
suppression on brain parenchymal contrast resolution and lesion detection in dogs. We
compared three sequences: T2-weighted images (T2w), STIR, and T2-weighted fluid attenuated
inversion recovery with chemical fat suppression (T2-FLAIR-FS) in dogs with
meningoencephalitis. Dogs with meningoencephalitis and dogs with idiopathic epilepsy were
retrospectively identified and anonymized. Evaluators recorded the presence or absence of
lesions within 12 predetermined brain regions on randomized sequences, viewing and scoring
each sequence individually. Additionally signal to noise ratios, contrast to noise ratios, and
relative contrast were measured in a reference population. STIR sequences had the highest
relative contrast between grey and white matter. While descriptively more lesions were
identified by evaluators on T2-FLAIR-FS images, there was no statistical difference in the
relative sensitivity of lesion detection between the sequences. Nor was there a statistical
difference in false lesion detection within our reference population. STIR may be favored for
enhanced anatomic contrast depiction in brain imaging. No benefit of the inclusion of a fat
suppressed T2-weighted FLAIR sequence was found.http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1740-82612016-03-31hb201
L-Edge Spectroscopy of Dilute, Radiation-Sensitive Systems Using a Transition-Edge-Sensor Array
We present X-ray absorption spectroscopy and resonant inelastic X-ray
scattering (RIXS) measurements on the iron L-edge of 0.5 mM aqueous
ferricyanide. These measurements demonstrate the ability of high-throughput
transition-edge-sensor (TES) spectrometers to access the rich soft X-ray
(100-2000eV) spectroscopy regime for dilute and radiation-sensitive samples.
Our low-concentration data are in agreement with high-concentration
measurements recorded by conventional grating-based spectrometers. These
results show that soft X-ray RIXS spectroscopy acquired by high-throughput TES
spectrometers can be used to study the local electronic structure of dilute
metal-centered complexes relevant to biology, chemistry and catalysis. In
particular, TES spectrometers have a unique ability to characterize frozen
solutions of radiation- and temperature-sensitive samples.Comment: 19 pages, 4 figure
Detection of the Power Spectrum of Cosmic Microwave Background Lensing by the Atacama Cosmology Telescope
We report the first detection of the gravitational lensing of the cosmic
microwave background through a measurement of the four-point correlation
function in the temperature maps made by the Atacama Cosmology Telescope. We
verify our detection by calculating the levels of potential contaminants and
performing a number of null tests. The resulting convergence power spectrum at
2-degree angular scales measures the amplitude of matter density fluctuations
on comoving length scales of around 100 Mpc at redshifts around 0.5 to 3. The
measured amplitude of the signal agrees with Lambda Cold Dark Matter cosmology
predictions. Since the amplitude of the convergence power spectrum scales as
the square of the amplitude of the density fluctuations, the 4-sigma detection
of the lensing signal measures the amplitude of density fluctuations to 12%.Comment: 4 pages, 4 figures, replaced title and author list with version
accepted by Physical Review Letters. Likelihood code can be downloaded from
http://bccp.lbl.gov/~sudeep/ACTLensLike.htm
High Tumour Cannabinoid CB1 Receptor Immunoreactivity Negatively Impacts Disease-Specific Survival in Stage II Microsatellite Stable Colorectal Cancer
BACKGROUND: There is good evidence in the literature that the cannabinoid system is disturbed in colorectal cancer. In the present study, we have investigated whether CB(1) receptor immunoreactive intensity (CB(1)IR intensity) is associated with disease severity and outcome. METHODOLOGY/PRINCIPAL FINDINGS: CB(1)IR was assessed in formalin-fixed, paraffin-embedded specimens collected with a consecutive intent during primary tumour surgical resection from a series of cases diagnosed with colorectal cancer. Tumour centre (nâ=â483) and invasive front (nâ=â486) CB(1)IR was scored from 0 (absent) to 3 (intense staining) and the data was analysed as a median split i.e. CB(1)IR <2 and â„2. In microsatellite stable, but not microsatellite instable tumours (as adjudged on the basis of immunohistochemical determination of four mismatch repair proteins), there was a significant positive association of the tumour grade with the CB(1)IR intensity. The difference between the microsatellite stable and instable tumours for this association of CB(1)IR was related to the CpG island methylation status of the cases. Cox proportional hazards regression analyses indicated a significant contribution of CB(1)IR to disease-specific survival in the microsatellite stable tumours when adjusting for tumour stage. For the cases with stage II microsatellite stable tumours, there was a significant effect of both tumour centre and front CB(1)IR upon disease specific survival. The 5 year probabilities of event-free survival were: 85±5 and 66±8%; tumour interior, 86±4% and 63±8% for the CB(1)IR<2 and CB(1)IRâ„2 groups, respectively. CONCLUSIONS/SIGNIFICANCE: The level of CB(1) receptor expression in colorectal cancer is associated with the tumour grade in a manner dependent upon the degree of CpG hypermethylation. A high CB(1)IR is indicative of a poorer prognosis in stage II microsatellite stable tumour patients
Psychiatric diagnoses, trauma, and suicidiality
BACKGROUND: This study aimed to examine the associations between psychiatric diagnoses, trauma and suicidiality in psychiatric patients at intake. METHODS: During two months, all consecutive patients (n = 139) in a psychiatric hospital in Western Norway were interviewed (response rate 72%). RESULTS: Ninety-one percent had been exposed to at least one trauma; 69 percent had been repeatedly exposed to trauma for longer periods of time. Only 7% acquired a PTSD diagnosis. The comorbidity of PTSD and other psychiatric diagnoses were 78%. A number of diagnoses were associated with specific traumas. Sixty-seven percent of the patients reported suicidal thoughts in the month prior to intake; thirty-one percent had attempted suicide in the preceding week. Suicidal ideation, self-harming behaviour, and suicide attempts were associated with specific traumas. CONCLUSION: Traumatised patients appear to be under- or misdiagnosed which could have an impact on the efficiency of treatment
Single hadron response measurement and calorimeter jet energy scale uncertainty with the ATLAS detector at the LHC
The uncertainty on the calorimeter energy response to jets of particles is
derived for the ATLAS experiment at the Large Hadron Collider (LHC). First, the
calorimeter response to single isolated charged hadrons is measured and
compared to the Monte Carlo simulation using proton-proton collisions at
centre-of-mass energies of sqrt(s) = 900 GeV and 7 TeV collected during 2009
and 2010. Then, using the decay of K_s and Lambda particles, the calorimeter
response to specific types of particles (positively and negatively charged
pions, protons, and anti-protons) is measured and compared to the Monte Carlo
predictions. Finally, the jet energy scale uncertainty is determined by
propagating the response uncertainty for single charged and neutral particles
to jets. The response uncertainty is 2-5% for central isolated hadrons and 1-3%
for the final calorimeter jet energy scale.Comment: 24 pages plus author list (36 pages total), 23 figures, 1 table,
submitted to European Physical Journal
Measurement of the inclusive and dijet cross-sections of b-jets in pp collisions at sqrt(s) = 7 TeV with the ATLAS detector
The inclusive and dijet production cross-sections have been measured for jets
containing b-hadrons (b-jets) in proton-proton collisions at a centre-of-mass
energy of sqrt(s) = 7 TeV, using the ATLAS detector at the LHC. The
measurements use data corresponding to an integrated luminosity of 34 pb^-1.
The b-jets are identified using either a lifetime-based method, where secondary
decay vertices of b-hadrons in jets are reconstructed using information from
the tracking detectors, or a muon-based method where the presence of a muon is
used to identify semileptonic decays of b-hadrons inside jets. The inclusive
b-jet cross-section is measured as a function of transverse momentum in the
range 20 < pT < 400 GeV and rapidity in the range |y| < 2.1. The bbbar-dijet
cross-section is measured as a function of the dijet invariant mass in the
range 110 < m_jj < 760 GeV, the azimuthal angle difference between the two jets
and the angular variable chi in two dijet mass regions. The results are
compared with next-to-leading-order QCD predictions. Good agreement is observed
between the measured cross-sections and the predictions obtained using POWHEG +
Pythia. MC@NLO + Herwig shows good agreement with the measured bbbar-dijet
cross-section. However, it does not reproduce the measured inclusive
cross-section well, particularly for central b-jets with large transverse
momenta.Comment: 10 pages plus author list (21 pages total), 8 figures, 1 table, final
version published in European Physical Journal
- âŠ